Elstein FSL ceramic infrared long panel heaters have two sockets with integrated litz fixing wires, which are pushed through holes in the mounting sheet and twisted behind it, so no special pre-punched holders or reflector plates are needed. They are designed for typical operating temperatures up to 550 °C and surface ratings up to 45 kW/m², and suit narrow, linear heating zones.
Thermocouple option: choose Without for the standard FSL heater, or With (Type K) for the official T-FSL version. The thermocouple version has an integrated type K (NiCr-Ni) thermocouple, for temperature control with TRD temperature controllers, TSE thyristor switching units and other Elstein accessories. This listing includes 1 standard and 1 thermocouple part numbers.
- Model: FSL (thermocouple versions: T-FSL)
- Heater size: 37 × 326 mm (Elstein catalogue)
- Surface rating: up to 45 kW/m²
- Typical operating temperature: up to 550 °C
- Maximum permissible temperature: 700 °C (marked on heater)
- Construction: ceramic long panel heater, two sockets with integrated litz fixing wires
- Standard operating voltage: 230 V
- Voltages in this listing: 230 V
- Standard wattages (Elstein FSL): 600 W
- Thermocouple (optional): integrated type K (NiCr-Ni)
Clearance stock — limited quantities.