Elstein HLF ceramic infrared panel heaters (long-neck socket) are designed for typical operating temperatures up to 630 °C and surface ratings up to 41.6 kW/m². HLF heaters were originally used to fit the Elstein BSF construction panel and remain the direct replacement for existing HLF installations. (For new designs Elstein recommends the energy-saving HTS series.)
Thermocouple option: choose Without for the standard HLF heater, or With (Type K) for the official T-HLF version. The thermocouple version has an integrated type K (NiCr-Ni) thermocouple, for temperature control with TRD temperature controllers, TSE thyristor switching units and other Elstein accessories. This listing includes 1 standard and 2 thermocouple part numbers.
The T-HLF heaters in stock are the long-neck version.
- Model: HLF (thermocouple versions: T-HLF)
- Heater size: 122 × 122 mm
- Mounting size: 125 × 125 mm
- Surface rating: up to 41.6 kW/m²
- Typical operating temperature: up to 630 °C (depends on wattage)
- Maximum permissible temperature: 700 °C (marked on heater)
- Construction: ceramic panel heater, long-neck socket
- Standard operating voltage: 230 V
- Voltages in this listing: 230 V
- Standard wattages (Elstein HLF): 250 W, 400 W, 650 W
- Thermocouple (optional): integrated type K (NiCr-Ni)
Clearance stock — limited quantities.